Ole hyvä ja odota...
Tuote on lisätty ostoskoriin. Näytä ostoskorin sisältö
040 571 2971 info@hcit.fi
Ostoskorisi on tyhjä

LENOVO S3200 SFF DUAL FC + ISCSI CONTR 4X8GB FC SFP + 6X600GB 10K SAS IN EXT

Etusivu Tallennus Ulkoiset asemat LENOVO S3200 SFF DUAL FC + ISCSI CONTR 4X8GB FC SFP + 6X600GB 10K SAS IN EXT
Hinnat näkyvät vain verkkokauppaan kirjautuneille käyttäjille.
LENOVO S3200 SFF DUAL FC + ISCSI CONTR 4X8GB FC SFP + 6X600GB 10K SAS   IN EXT (6411E36)

LENOVO S3200 SFF DUAL FC + ISCSI CONTR 4X8GB FC SFP + 6X600GB 10K SAS IN EXT

Tuotekoodi:
6411E36
EAN:
0889488098439
  • Asennettu 35.6TB
  • Liitäntä FC, iSCSI
  • Max levyt 24
  • RAID Kyllä
  • Tyyppi Rack (2U)
  • Levyn koko 2.5"
Kuvaus

Lenovo Storage S3200


The Lenovo® Storage S3200 (shown in the following figure) is a versatile storage system that is designed to provide simplicity, speed, scalability, security, and high availability for small to large businesses. The S3200 SAN array delivers enterprise-class storage management technology in a cost-effective solution with a wide choice of host connectivity options, flexible drive configurations, and enhanced data management features.

The S3200 is a perfect fit for for a wide range of workloads, from specialized workloads such as big data and analytics, video surveillance, media streaming, and private clouds to general purpose workloads such as file and print serving, web serving, e-mail and collaboration, and OLTP databases. The S3200 is also suited very well for secure archive storage or a consolidated backup solution.


Features:

  • Versatile, scalable storage with a single controller, or dual active/active controller configurations for high availability and performance.
  • Flexible host connectivity to match diverse client needs with support for 6/12 Gb SAS (SAS controller) or 1/10 Gb iSCSI or 4/8/16 Gb FC connectivity (FC and iSCSI controller) or both iSCSI and FC at the same time.
  • 6 Gb SAS drive-side connectivity with support for 12x 3.5-inch large form factor (LFF) or 24x 2.5-inch small form factor (SFF) drives in the controller enclosure; scalable up to 96 LFF drives per system with the attachment of Lenovo Storage E1012 expansion enclosure (12x LFF drives each) or up to 192 SFF drives per system with the attachment of Lenovo Storage E1024 expansion enclosure (24x SFF drives each) to satisfy growing needs for storage capacity and performance.
  • Flexibility in storing data on high performance SAS SSDs, performance-optimized enterprise SAS HDDs, or capacity-optimized enterprise NL SAS HDDs; mixing and matching drive types and form factors within a single system to perfectly meet performance and capacity requirements for various workloads.
  • Support for self-encrypting drives to allow clients to secure their sensitive data and to comply with various security regulations when required.
  • Rich set of standard functions available at no additional cost, including virtualized storage pools, snapshots, thin provisioning, rapid rebuild, real-time HDD tiering, and SSD read cache.
  • Optional licensed functions, including higher number of snapshots for more scalability, real-time SSD tiering for boosting IOPS performance, and asynchronous replication for 24x7 data protection and disaster recovery.
  • Intuitive, web-based GUI for easy system setup and management.
  • Designed to comply with NEBS and MIL-STD requirements.
  • Designed for 99.999% availability.


Specifications:

Form factor S3200 controller enclosure: 2U rack mount
E1012 or E1024 drive expansion enclosure: 2U rack mount
RAID controller configuration Two types of controllers:
  • S3200 SAS controller
  • S3200 FC and iSCSI controller
Single or dual RAID controller configurations supported. Single controller systems can be upgraded to dual controller non-disruptively. Both controllers in the system must be the same.
RAID levels RAID 1, 5, 6, and 10
RAID controller cache 6 GB per controller. Battery-free cache protection with flash memory and supercapacitors. Low latency cache mirroring protection for dual controller configurations.
Drive bays Up to 192 SFF drive bays per system:
  • 24 SFF drive bays in the S3200 controller enclosure
  • 24 SFF drive bays in the E1024 drive expansion enclosure; up to 7x E1024 enclosures
Up to 96 LFF drive bays per system:
  • 12 LFF drive bays in the S3200 controller enclosure
  • 12 LFF drive bays in the E1012 drive expansion enclosure; up to 7x E1012 enclosures
Intermix of SFF and LFF enclosures is supported.
Drive technologies SAS and NL SAS HDDs and SEDs; eMLC SAS SSDs. Intermix of HDDs and SSDs is supported. Intermix of SEDs with HDDs or SSDs is not supported.
Drive connectivity

Dual-ported 6 Gb SAS drive attachment infrastructure.

Controller enclosure with one or two RAID controllers (ports per one controller):
  • 24x 6 Gb SAS internal drive ports (SFF chassis)
  • 12x 6 Gb SAS internal drive ports (LFF chassis)
  • 1x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion port for the attachment of the external drive enclosures
Drive expansion enclosure with one or two expansion modules (ports per one module):
  • 24x 6 Gb SAS internal drive ports (SFF chassis)
  • 12x 6 Gb SAS internal drive ports (LFF chassis)
  • 2x 6 Gb SAS x4 (Mini-SAS SFF-8088) expansion ports (IN and OUT) for the daisy chained attachment of the external drive enclosures
Drives SFF drives:
  • 400 GB, 800 GB, and 1.6 TB SAS SSDs (3 DWD and 10 DWD)
  • 400 GB and 800 GB SAS SED SSDs (10 DWD)
  • 3.84 TB SAS SSDs (1 DWD)
  • 300 GB and 600 GB 15K rpm SAS HDDs
  • 600 GB, 900 GB, 1.2 TB, and 1.8 TB 10K rpm SAS HDDs
  • 1 TB and 2 TB 7.2K rpm NL SAS HDDs
LFF drives:
  • 400 GB SAS SSDs (10 DWD)
  • 600 GB and 900 GB 10K rpm SAS HDDs
  • 2 TB, 4 TB, 6 TB, 8 TB, and 10 TB 7.2K rpm NL SAS HDDs
Storage capacity Up to 960 TB (96x 10 TB NL SAS HDDs)
Host connectivity S3200 SAS controller: 4x 6/12 Gb SAS host ports (Mini-SAS HD, SFF-8644)
S3200 FC and iSCSI controller: 4x SFP/SFP+ host ports with two built-in dual-port CNCs (each port on the same CNC must have the same connectivity type, different CNCs might have different connectivity types)
CNC host port options (per each CNC on the RAID controller):
  • 2x 1 Gb iSCSI SFP (1 Gb speed, UTP, RJ-45)
  • 2x 10 Gb iSCSI SFP+ (1/10 Gb speeds, SW fiber optics, LC)
  • 2x 8 Gb FC SFP+ (4/8 Gb speeds, SW fiber optics, LC)
  • 2x 16 Gb FC SFP+ (4/8/16 Gb speeds, SW fiber optics, LC)
  • 2x 10 Gb iSCSI SFP+ DAC cables
Host operating systems Microsoft Windows Server 2012 R2 and 2016; Red Hat Enterprise Linux (RHEL) 6 and 7; SUSE Linux Enterprise Server (SLES) 11 and 12; VMware vSphere 5.5, 6.0, and 6.5.
Standard software features Intelligent Real-time Tiering for HDDs, Virtualized Storage Pools, Thin Provisioning, SSD Read Cache, Rapid RAID Rebuild, Snapshots - up to 128 targets.
Optional software features Intelligent Real-time Tiering for SSDs, Snapshots - up to 1,024 targets, Asynchronous Replication.
Performance Dual controller configuration:
  • Up to 120,000 random read IOPS (4 KB blocks)
  • Up to 6.4 GBps sequential read throughput (512 KB blocks)
  • Up to 5.3 GBps sequential write throughput (512 KB blocks)
Configuration maximums Per system:
  • Maximum number of virtual storage pools: 2 (1 per controller)
  • Maximum number of logical volumes (total/mapped): 2,048/1,024
  • Maximum logical volume size: 128 TB
  • Maximum number of drives in a drive group: 16
  • Maximum number of drive groups: 32
  • Maximum global spares: 16
  • Maximum number of initiators: 8,192 (1,024 per port)
  • Maximum number of hosts in a host group: 256
  • Maximum number of host groups: 32
  • Maximum number of initiators per host: 128
  • Maximum number of snapshots: 1,024 (requires an optional license)
  • Maximum number of replication peers: 1 (requires an optional license)
  • Maximum number of replication volumes: 32 (requires an optional license)
Cooling Redundant cooling with two fans that are built into power supplies.
Power supply Two redundant hot-swap 595 W AC power supplies.
Hot-swap parts RAID controllers, expansion modules, SFP/SFP+ transceivers, drives, power supplies/fans.
Management interfaces Web-based graphical user interface (GUI); Telnet, SSH, or Direct Connect USB command-line interface (CLI); HTTP scripting with XML encoding; SNMP and e-mail notifications
Security features Secure Socket Layer (SSL), Secure Shell (SSH), self-encrypting drives (SEDs)
Warranty Three-year customer-replaceable unit, parts only limited warranty with 9x5 next business day.
Service and support Optional warranty service upgrades are available through Lenovo: on-site support, 24x7 coverage, 4-hour response time, 1-year or 2-year warranty extensions, Hard Drive Retention.
Dimensions
  • LFF chassis: Height: 87 mm (3.4 in), width: 447 mm (17.6 in), depth: 523 mm (20.6 in)
  • SFF chassis: Height: 89 mm (3.5 in), width: 447 mm (17.6 in), depth: 519 mm (20.5 in)
Weight
  • S3200 LFF: Minimum: 18.4 kg (40.6 lb); Maximum: 28.2 kg (62.2 lb)
  • S3200 SFF: Minimum: 18.5 kg (40.8 lb); Maximum: 25.0 kg (55.2 lb)
  • E1012: Minimum: 16.8 kg (37.0 lb); Maximum: 26.6 kg (58.6 lb)
  • E1024: Minimum: 16.9 kg (37.2 lb); Maximum: 23.4 kg (51.6 lb)

Huomioi, että kuva on suuntaa-antava ja varsinainen tuote saattaa ulkoasultaan poiketa tuotekuvasta (esim. tietokoneisiin ei välttämättä sisälly näyttöä, vaikka kuvassa sellainen olisikin). Jos tuotenimikkeessä on eri tiedot kuin tuotekuvauksessa, tuotenimikkeen tieto on oikein. Jos jokin asia jää epäselväksi, lähetä sähköpostia tukeen ennen tuotteen tilaamista.